    摘要:

    目前减震结构的附加阻尼比计算都需要先计算出结构的动力反应,并进行复杂的迭代过程,且在计算中一般都仅考虑激励频率等于结构基频的情况。基于非线性黏滞阻尼器,提出了一种不需计算结构动力反应,只根据结构特性、激励频率和阻尼器参数直接求解结构附加阻尼比的计算方法。分析了目前常用的几种附加阻尼比的计算方法,推导出了减震体系在简谐激励下,当激励频率等于结构基频时,不需要计算结构动力反应,且不需要迭代过程的附加阻尼比计算公式;研究了不同阻尼指数下激励频率对附加阻尼比计算取值的影响,并提出非共振情况下附加阻尼比的简化计算公式,在此基础上以反应谱平均周期为地震动的激励频率,给出了考虑激励频率且不需要计算结构动力反应的附加阻尼比简化计算方法;通过算例和非线性时程分析结果进行对比,验证了所提出方法的准确性。

    Abstract:

    At present,it is necessary for the calculation of the supplemental damping ratio of the aseismic structure to calculate the dynamic response of the structure and perform the iterative process. In addition,generally only the case where the excitation frequency is equal to the fundamental frequency of the structure is considered. Based on the nonlinear viscous damper,a calculation method that without calculating the structural dynamic response directly obtains the structural supplemental damping ratio based on structural characteristics,excitation frequency and damper parameters is proposed. Firstly,several frequently used methods of calculating supplemental damping ratio are analyzed. Then,the calculation formula of the supplemental damping ratio for the excitation frequency equals to the fundamental frequency of the structure,and without calculating the structural dynamic response and the iterative process is deduced. By studying on the influence of the excitation frequency on the calculation of the supplemental damping ratio for different damping indexes,a simplified calculation formula for supplemental damping ratio in the case of non-resonance is proposed. On this basis,taking response spectrum average period as the excitation frequency of the ground motion,a simplified calculation method of the supplemental damping ratio considering the excitation frequency and no need to calculate the structural dynamic response is given. Finally,the accuracy of the proposed method is verified by comparing the results of the example with the results of nonlinear time history analyses.

    参考文献
    相似文献
    引证文献
引用本文

杜东升,刘言杰,徐庆阳.黏滞阻尼器考虑激励频率影响的附加阻尼比简化计算[J].振动工程学报,2021,34(1):29~37.[DU Dong-sheng, LIU Yan-jie, XU Qing-yang. Simplified calculation of supplemental damping ratio of viscous damper considering excitation frequency[J]. Journal of Vibration Engineering,2021,34(1):29~37.]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-05-12
  • 出版日期:
文章二维码
您是第位访问者
振动工程学报 ® 2025 版权所有
技术支持:北京勤云科技发展有限公司